Газораспределительная панель BM55-2A
Product features
- Wall- and cabinet-mounting pressure control panels with fully automatic change-over function
- For non-corrosive gases up to quality 5.0
- Simple outlet pressure adjustment
- Minimised pressure difference between left and right hand side outlet pressure due to Ambimat
- Maximum emptying of gas cylinders
- Laboratory-style design
- Ergonomically designed
- Modular design (to be extended to 2x2, 2x3 etc. cylinders)
- Filter at the process gas inlet valve
- Diaphragm-type shut-off valves optimised for low internal volume with On/Off position indicator
- Regulator with high control accuracy and integrated relief valve
- Designed for easy installation
- Tested for use with oxygen
- Suitable for inlet pressure values up to 300 bar
- Compact design especially for installation into safety cabinets for gas cylinders
Technical data | ||
---|---|---|
Type: | single-stage | |
Inlet pressure P1: | max. 100/200/300 bar | |
Outlet pressure P2: |
max. 10 / 20 / 50 / 100 / 200 bar |
|
Materials: Body regulator and valves: Valve seat regulator: Valve seat shut-off valve: Diaphragm regulator: Diaphragm valve: Soft goods regulator: Soft goods Ambimat: Filter regulator: Filter Ambimat: |
chrome-plated brass PA 11 PVDF Hastelloy C276 Hastelloy C276 EPDM FKM Sintered SS 316L Sintered bronze |
|
Inlet connector: |
stainless steel compression fitting 6 x 1 mm |
|
Temperature range: | -15°C to +60°C | |
Leak rate: (to atmosphere) (via seat) |
1 x 10-8 mbar l/s He 1 x 10-6 mbar l/s He |
|
Manometer: |
safety pressure gauges ISO5171/K11.6/NG50 |
|
Weight: | approx. 10 kg |
You can order the Ambimat pressure control panel for five different outlet pressure ranges: 10 / 20 / 50 / 100 / 200 bar
The change-over pressure must always be above the minimum outlet pressure to make sure that a pressure regulation is possible.
If the required outlet pressure exceeds the change-over pressure, then there is the possibility to raise the change-over pressure. Connecting the outlet of the pressure regulator with the Ambimat raises the change-over pressure by approximately 90% of the outlet pressure.
Скачать инструкцию в формате PDF